Unosi iz tabele: vt131

idh_idstatusdatum_neispvrijemeh_vazd_neispopisuser1_iddatum_opravkeh_vazd_opravkeradoviuser2_idaktivanvrijeme2user1_vrijemeuser2_vrijemeDetalji
35332032021-11-0100:00:096299.40Fire extinguisher test and inspection is due on 14.10.2021262022-01-126299.40Completed26000:00:1211:49:2513:58:32Detalji
35342032021-11-0100:00:096299.40Hysraulic oil sample due to phase #4 completion262022-01-216301.00Completed26000:00:1011:51:1213:55:48Detalji
35352032021-11-0100:00:096299.40Tap hammer inspection of vertical fin spar is due at 6303.4 hrs262022-01-126299.40Completed26000:00:1111:53:2913:59:13Detalji
35362032021-11-0100:00:096299.40Inverter inspection is due at 6303.4 hrs262021-11-086299.40Completed26000:00:1311:55:3311:56:13Detalji
35372032021-11-0100:00:096299.40DYE penetrant inspection of 42 stepeni G/B gears due at 6303.4262021-12-156299.40Completed26000:00:1411:58:0311:58:44Detalji
35382032021-11-0100:00:096299.40Main rotor blade PN:204-011-250-113, grip pad and plates inspection of due at 6303.4 hrs262022-01-046299.40Completed26000:00:1412:00:5913:56:39Detalji
35392032021-11-0100:00:096299.40Sloppy link inspection due at 6303.4 hrs262021-11-186299.40Completed26000:00:1212:02:0612:02:41Detalji
35402032021-11-0100:00:096299.40X-ray inspection of tail boom vertical fin spar is due at 6303.4 hrs262021-12-276299.40Completed by compamy "ORAO". Results OK! Documentation stored in QC x-ray file26000:00:0912:06:4112:10:23Detalji
35412012021-11-0100:00:096299.40Sumnja na ispravnost rada glavnog goeivnog ventila ("MAIN CHUT OFF VALVE")262021-12-156299.40Ventil zamijenjen26000:00:1412:13:2612:14:14Detalji
35422042021-11-0100:00:096299.40Gumena zaštita na oklopu motora brisača (R/H) odlijepljena262022-01-126299.40Zamijenjeno26000:00:1312:16:4414:03:24Detalji
35432032021-11-0100:00:096299.40Voltage regulator setting due to phase #4 completion262022-01-196299.40Completed26000:00:1312:18:1113:44:35Detalji
35442032021-11-0900:00:126299.40Retorqe internal oil filter nuts at next run up to 90 in/lb262022-01-176299.40Completed26000:00:1212:20:2413:57:40Detalji
35452042021-11-1000:00:116299.40Left and right and inlet filter danaged262021-11-106299.40Replaced26000:00:1312:24:1812:24:58Detalji
35462012021-11-1500:00:106299.40Check M/R mast for susportal creck unclerbline in area of atast beat262021-11-166299.40Completed penetrant inspection.There is no sign of craqck26000:00:1312:28:3712:52:27Detalji
35472012021-11-2900:00:126299.40There is excessive playon stabilaser bar assy support assy bearings262021-12-236299.40Replaced one bearing on stabilizer bar support26000:00:1012:54:5212:56:10Detalji
35482032021-12-0600:00:096299.40Replaced bearing on all four h/b assy due to low retarement life262021-12-236299.40Replaced bearings26000:00:1013:00:1913:01:26Detalji
35492012021-12-0600:00:096299.40Piting codescion of 42 stepeni G/B case excecd limits262021-12-236299.40Replaced 42 stepeni G/B26000:00:1013:04:5413:05:43Detalji
35502032021-11-0100:00:096299.40Potrebno je uraditi inspekciju FCU262021-12-136299.40Inspekcija FCu urađena po faznoj knjizi A 2622/65-0980126000:00:1213:06:4813:08:34Detalji
35512012021-12-2900:00:106299.40Pilot adjustor belerank bearing binding (force gradiant to adjuster assy)262022-01-056299.40Replaced26000:00:1413:12:0114:05:00Detalji
3552232022-01-0400:00:08801.35Tehnički dan.132022-01-04801.35Izvršen.13000:00:1213:37:5413:38:18Detalji