3075852021-04-0100:00:10661.03Obilazak i vizuelna provjera stanja helikoptera. 132021-04-01661.03Izvršeno. 13000:00:1112:22:2512:23:00Detalji
30762212021-03-3100:00:129429.80Damper link red and white rod end has excesive play.262021-03-319429.80Replaced red and white rod end. Insp ok.26000:00:1309:31:1709:32:17Detalji
30772212021-03-3100:00:129429.80P/C link red and white rod end has excesive play.262021-03-319429.80Replaced red and white rod end. Insp ok.26000:00:1309:33:2209:34:06Detalji
30782232021-04-0200:00:149430.40Ground run for 5 minutes at 6600 engine 324 rotor RPM and after shutdown. Purge M/R hub with grease until grease passes trough grip plate relief fittings and trunnion seals.262021-04-089430.40Completed.26000:00:0909:37:4909:38:35Detalji
30792232021-04-0200:00:149430.40After first flight purge lubricate again.262021-04-099432.20Completed.26000:00:1409:39:4014:30:50Detalji
30802232021-04-0200:00:149430.40After 10 flight hours @ 9440.5 acft hrs purge lubricate again M/R hub.262021-04-159434.10C/F26000:00:1309:43:5314:30:04Detalji
30812232021-04-0200:00:159430.40After 50 flight hours @ 9480.5 acft hrs perform lubrication iaw da form 2408-18.262021-04-159434.10C/F26000:00:1309:45:2014:29:43Detalji
30822232021-04-0200:00:159430.40Perform functional test on bleed air heater/muff heater system. (Inspection reentered from phase book)262021-04-089430.40Insp ok!26000:00:0909:46:5309:47:49Detalji
30832232021-04-0200:00:159430.40MOC required due to replacement of M/R hub.262021-04-089430.40Completed.26000:00:0909:48:3909:49:06Detalji
30842232021-04-0200:00:159430.40M/R track and balance check required due to replacement of M/R hub.262021-04-089432.20M/R vibrations are within specified limits except measure state letdown (0.27 IPS).26000:00:1409:50:1009:51:28Detalji
30852232021-04-0500:00:149430.40Visual inspection of T/B vertical fin spar due!262021-04-059430.40Completed.26000:00:1409:52:2009:52:43Detalji
30862212021-04-0800:00:109430.40M/R high vibration!262021-04-089430.40Completed.26000:00:1409:54:2109:54:53Detalji
30872212021-04-0800:00:109433.60M/R blade out of track! (0.79 inch)262021-04-089430.40P/C red extended 3 flat. Insp ok.26000:00:1009:55:5309:57:36Detalji
30882212021-04-0800:00:129430.40M/R high vibrations!262021-04-089431.00P/C red shorten 2.5 flat trim tab plus2*. Insp ok.26000:00:1209:58:0810:00:32Detalji
30892212021-04-0800:00:129431.30M/R high vertical vibrations!262021-04-089431.30P/C red extended 2.5 flat, white blade added 18g, trim tab plus1.5*. Insp ok.26000:00:1210:01:3310:02:56Detalji
30902212021-04-0800:00:139431.60M/R high vertical vibrations!262021-04-089431.60P/C extend -0.5 flat. Insp ok.26000:00:1310:04:2210:05:08Detalji
30912212021-04-0800:00:149432.20Main inverter produce very strange noise!262021-04-099432.20Izvršena zamjena neispravnog pretvarača. Provjereno na zemlji, radi ispravno, Podešeni napon 112 V.26000:00:1110:06:1610:08:10Detalji
30922232021-04-0800:00:149432.20Fire detector test switch unreliable!262021-04-099432.20Izvršena zamjena test prekidača. Provjereno na zemlji, radi ispravno.26000:00:1310:09:2710:10:19Detalji
30932232021-04-0900:00:089432.20Visual inspection of T/B vertical fin spar due.262021-04-099432.20Completed!26000:00:1210:11:1110:11:33Detalji
30942212021-04-0900:00:159432.70Free weeling cluch unable to disengage!262021-04-099432.90Adjusted on 68. Insp ok.26000:00:1610:12:2410:13:00Detalji