Unosi iz tabele: vt131

idh_idstatusdatum_neispvrijemeh_vazd_neispopisuser1_iddatum_opravkeh_vazd_opravkeradoviuser2_idaktivanvrijeme2user1_vrijemeuser2_vrijemeDetalji
28472032020-10-1400:00:106153.40High vertical vibration susp sntared from phase book262020-10-266157.20Completed vibration check of M/R (All vibration limits are within specified limits except measure state 110 kt vertical 0.25 ips)26000:00:1512:02:5311:23:55Detalji
28482032020-10-1400:00:106153.40Check T/R track and balabce due to phase #3 completion262020-10-146153.40Entry made in eror! see entry below!26000:00:1212:04:4112:05:52Detalji
28492012020-10-1400:00:126153.40Tail rotor vibration out of accepta ble limit (0.25 ips)262020-10-146153.40Added 8 GR weight to target blade on cord. Inspect OK26000:00:1212:07:2612:08:59Detalji
28502012020-08-2500:00:106153.40Phase #3 in progres262020-10-146153.40Phase #3 completed. INSP OK!26000:00:1312:10:5912:39:18Detalji
28512032020-09-0800:00:126153.40Engine N2 vibretion check due262020-10-266157.20Completed (All vibration limits are within specified limits)26000:00:1512:12:2010:45:43Detalji
28522032020-09-0900:00:126153.40"LTF" potrebno uraditi zbog instalacije "FCU"262020-10-266157.20LTF OK!26000:00:1412:13:5011:19:41Detalji
28532012020-10-1900:00:116153.40FCU leaking262020-10-216153.40Reentered to phase book!26000:00:1112:36:2412:13:17Detalji
28551512020-10-2000:00:108438.80T/R hanger bearing & support fitting inspection is due302020-10-278438.80Inspect completed.25000:00:1415:17:4816:29:50Detalji
2856132020-10-2000:00:08808.40Tehnički dan. 132020-10-20808.40Izvršen. 13000:00:1209:22:2409:22:44Detalji
2857132020-10-2000:00:11808.40Izvršiti operativnu provjeru u cilju redovnog održavanja. 132020-10-20808.42Izvršeno. 13000:00:1109:23:4609:24:17Detalji
28582032020-10-2000:00:136153.40Engine oil results abnormal analysis findigs hihh wear metal content, lab recomiaendations do not change oil. Submit hot resample.262020-10-226155.00Special oil sample taken after flight!26000:00:1509:29:4512:15:24Detalji
2859232020-10-2000:00:08800.33Tehnički dan. 132020-10-20800.33Izvršeno.13000:00:1209:30:0109:30:30Detalji
28602032020-10-2000:00:136153.4042 stepeni gearboxoil results abnormal analysis findings water exceeds PPM limit. Lab recommendations resamole at the end of the next flight day/cycle.262020-10-226155.00Special oil sample taken after flight!26000:00:1509:34:1312:16:31Detalji
2861232020-10-2000:00:11800.33Operativna provjera u cilju redovnog održavanja.132020-10-20800.35Izvršeno. 13000:00:1109:42:4609:43:15Detalji
28622032020-10-2100:00:086153.40Preventive maintenance daily due262020-10-216153.40Completed26000:00:1113:56:2613:59:53Detalji
28632032020-10-2100:00:086153.40M/R blade grip and plates inp. of262020-10-216153.40Completed26000:00:1213:57:2714:00:16Detalji
28642032020-10-2100:00:086153.40M/R blade PN:204-011-250-113 trailing edge inspection (part II)262020-10-216153.40Completed26000:00:1213:59:2014:00:45Detalji
28652032020-10-2100:00:086153.40Preventive mainteance daily due262020-10-216153.40Completed26000:00:1112:18:4212:21:46Detalji
28662032020-10-2100:00:086153.40M/R blade grip and plates insp. of262020-10-216153.40Completed26000:00:1212:19:3612:22:12Detalji
28672032020-10-2100:00:086153.40M/R blade P/N 204-011-250-113 trailing edge inspection (PART II)262020-10-216153.40Completed26000:00:1212:20:4912:22:36Detalji