Unosi iz tabele: vt131

idh_idstatusdatum_neispvrijemeh_vazd_neispopisuser1_iddatum_opravkeh_vazd_opravkeradoviuser2_idaktivanvrijeme2user1_vrijemeuser2_vrijemeDetalji
2659232020-07-0700:00:08800.22Izvršiti pregled u tehničkom danu sa ručnim okretanjem kola turbine kompresora lijevog i desnog motora. 132020-07-07800.22Izvršeno. 13000:00:1110:24:4310:24:59Detalji
2660832020-07-0800:00:09661.03Pregled u tehničkom danu sa ručnim okretanjem kola turbine kompresora lijevog i desnog motora. 132020-07-08661.03Izvršeno. 13000:00:1209:27:3209:27:54Detalji
26612512020-07-1300:00:098037.00Inspect T/R hanger bearing support fittings.252020-07-178037.00Completed25000:00:1211:44:5414:44:17Detalji
2662232020-07-1300:00:08800.22Tehnički dan. 132020-07-13800.22Izvršen.13000:00:1213:00:2613:01:13Detalji
2663232020-07-1300:00:08800.22Operativna provjera nakon 6 mjesečnog povremenog pregleda. 132020-07-13800.26Izvršena.13000:00:1113:02:3713:03:01Detalji
2664132020-07-1300:00:08808.28Pregled u tehničkom danu. 132020-07-13808.28Izvršen. 13000:00:1210:48:4310:49:11Detalji
2665132020-07-1300:00:08808.28Operativna provjera nakon 6 mjesečnog povr. pregleda. 132020-07-13808.31Izvršeno. 13000:00:1110:52:4710:53:51Detalji
26663512020-07-1500:00:121360.10Neispravan indukcioni kalem serijski broj 6807.112021-11-231360.10Urađena pir opravka u AS IKAR 16.09.2021.12000:00:1012:46:3112:26:23Detalji
26673112020-07-1500:00:121839.40Neispravan obrtomjer.112021-04-291839.40Izvršena kontrolisana zamjena dijela.11000:00:1112:48:4911:30:46Detalji
2668832020-07-1500:00:08661.03Pregled u tehničkom danu. 132020-07-15661.03Izvršen. 13000:00:1211:35:3811:35:56Detalji
2669932020-07-1500:00:08989.04Tehnički dan sa ručnim okretanjem kola TK lijevog i desnog motora. 132020-07-15989.04Izvršen. 13000:00:1111:38:2011:38:48Detalji
26703932020-07-2000:00:131804.15Izvršiti pregled PP aparata 25.07.2020352020-08-041811.4535000:00:0812:52:4208:11:48Detalji
26711512020-07-2200:00:088425.40VHF ineperative.252020-07-228425.60pogresan upis sati naleta helikoptera.25000:00:1412:38:0614:07:57Detalji
26721512020-07-2200:00:088425.60VHF inoperative.252020-07-238425.60Izvrsena inspekcija i ciscenje konektora primopredajnika i fiski. Provjera na zemlji-ispravno.25000:00:1014:08:5212:29:43Detalji
26732032020-07-2400:00:086140.60Insp. T/R hanger bearing support fittings (600H/12M) is prolonged but NLT 24AUG20.252020-09-076153.40Inspection overdue (see next entry)26000:00:1008:47:5011:16:34Detalji
26742032020-07-2400:00:086140.60Insp/clean and lube T/R couplings and bearings (600H/12M) is prolongded but NLT 24AUG20.252020-09-076153.40Inspection overdue (see next entry)26000:00:1008:49:4411:22:05Detalji
26753932020-07-2700:00:111811.45Izvršiti provjeru tripoda radi pojave pukotine.122020-07-271811.45izvršena provjera tripoda - NEISPRAVNO12000:00:1212:11:4912:17:23Detalji
26763912020-07-2700:00:111811.45Izvršiti skidanje i postavljanje repne turbine radi provjere tripoda.122020-07-271811.45Izvršeno skidanje i postavljanje repne turbine.12000:00:1212:14:0512:15:37Detalji
26773912020-07-2700:00:121811.45Pojava pukotine na nosaču repnog reduktora pored vara ka prednjem paoku na lijevoj strani.122020-08-181811.45Izvršena ugradnja ispravnog tripoda.11000:00:1412:19:3314:45:13Detalji
2678132020-08-0300:00:08808.31Pregled u tehničkom danu52020-08-03808.31Izvršeno5000:00:1208:41:1908:41:41Detalji